Continuous Emissions Monitoring System

The new Thermo Scientific Particulate Matter Continuous Emissions Monitoring System (PM CEMS) improves accuracy by offering true mass concentration that meets the National Institute of Standards and Technology (NIST)-traceable standards for customers seeking to comply with the Utility Mercury and Air Toxics Standards (MATS), Portland Cement Maximum Achievable Control Technology (MACT), and the Industrial/Commercial/Institutional Boiler MACT.

The PM CEMS is designed with dual monitoring technology that includes both light scattering (Nephelometry) and tapered element oscillating microbalance (TEOM, a proprietary Thermo Fisher technology) to measure and record effluent particulate emissions coming off the stack. Designed for maximum accuracy, the proprietary TEOM technology measures the true mass concentration of particulate matter emissions that are designed to provide precise and accurate readings that simplify regulatory compliance and facilitate successful audits.

In addition, the PM CEMS offers: fully automated QA/QC procedures; the only dual monitoring solution for performance specification 11 compliance on the market; and a portfolio of complementary products that provide a total solution for MACT regulations, including the Thermo Scientific Mercury Freedom System, OMNI FTIR CEMS and ARKE S03 System. Thermo Fisher Scientific, www.thermoscientific.com 

Related posts